Товары и услуги

40% Glass Fiber Polyphthalamide — Examid® PPA GF40

Description

Examid® PPA GF40 is a polyphthalamide reinforced with 40% glass fiber. The semi-aromatic matrix places the material in the high-temperature class: melting point of 310 °C, HDT of 275 °C at 1.80 MPa — a range inaccessible to aliphatic PA66 GF.

PPA's second advantage is moisture uptake of 0.9% (23 °C, 50% RH), 2.5–3× lower than PA66: mechanics and dimensions stay stable in humid environments. Tensile modulus of 13,500 MPa, strength of 155 MPa, Charpy unnotched impact of 100 kJ/m². Dielectric strength of 27 kV/mm supports E&E service.

The niche: connectors and power-electronics housings, engine-zone parts, metal and PPS replacement in hot humid assemblies. Class analogs — Ultramid® Advanced N GF, Grivory® HTV. Processing: melt 320–335 °C, mold 135–165 °C — hot mold temperature control required.

High-temperature PPA GF40: HDT of 275 °C and minimal moisture dependency
Applications: connectors and power-electronics housings, engine-zone parts, high-temperature structural assemblies, metal and PPS replacement in hot humid environments.
Typical properties:
parameter
unit
value
General properties:
Density
g/cm³
1.46 (ISO 1183-1)
Glass fiber content
%
40 (ISO 3451-1)
Moisture absorption (23 °C, 50% RH)
%
0.9 (ISO 62)
Mechanical properties:
Tensile modulus
MPa
13500 (ISO 527-2)
Tensile strength
MPa
155 (ISO 527-2)
Strain at break
%
3.5 (ISO 527-2)
Flexural modulus
MPa
9300 (ISO 178)
Flexural strength
MPa
205 (ISO 178)
Charpy unnotched impact, 23 °C
kJ/m²
100 (ISO 179)
Thermal properties:
Melting point, DSC
°C
310 (ISO 11357-1/-3)
HDT (1.80 MPa)
°C
275 (ISO 75-1/-2)
Burning behavior (3.0 mm)
HB (UL 94)
Electrical properties:
Dielectric strength
kV/mm
27 (IEC 60243-1)
Processing recommendations:
Melt temperature
°C
320–335
Mold temperature
°C
135–165
Molding pressure
MPa
70–90
Injection speed
medium to high
Указанные показатели измеряются по внутренним методикам, близким к соответствующим ISO, ГОСТ Информация носит ознакомительный характер, рекомендуем использовать техническую информацию после согласования с поставщиком и подписания нормативно-технической спецификации

FAQ

When PPA instead of PA66 GF?

When service temperature exceeds 150 °C or humid-environment stability is required: HDT of 275 °C and 0.9% moisture uptake vs 250 °C and ~2.5% for PA66 GF.

What to consider when molding PPA?

Melt at 320–335 °C and a hot mold at 135–165 °C (oil temperature control) are mandatory for full crystallization and stable geometry.

Which analogs does it replace?